Eyeworld

JAN 2013

EyeWorld is the official news magazine of the American Society of Cataract & Refractive Surgery.

Issue link: https://digital.eyeworld.org/i/104833

Contents of this Issue

Navigation

Page 32 of 70

30 EW CORNEA January 2013 Cornea editor's corner of the world Cornea surgeons compare thin DSAEK and DMEK as options for endothelial keratoplasty procedures by Ellen Stodola EyeWorld Staff Writer A dvances in endothelial keratoplasty have occurred at a rapid rate considering that less than a decade ago corneal specialists were still performing penetrating keratoplasty for all endothelial replacement. The latest innovation in endothelial surgery is Descemet's membrane endothelial keratoplasty (DMEK). This technique eliminates the stromal carrier used in Descemet's stripping automated endothelial keratoplasty (DSAEK) and in theory should result in better vision. However, the DMEK procedure has been slow to be adopted by most corneal surgeons due to the higher complication rate. Complications in DMEK include increased early endothelial cell loss, increased graft detachments, and loss of donor tissue in the preparation of the graft. In addition, the tissue is more difficult to handle once in the anterior chamber, resulting in longer surgical time. Recently a variation on the traditional DSAEK has been introduced that may provide the benefits of DMEK without the complications. Data has shown that if the donor tissue in DSAEK is cut thinner than in traditional tissue preparation, the visual outcomes are improved. In addition, the newer insertion devices now available make this "thin DSAEK" tissue easier to handle and insert into the eye, reducing trauma to the endothelium. As we continue to strive for better outcomes and reduced complications in endothelial replacement surgery, we need studies to determine if "thin DSAEK" produces similar visual outcomes to DMEK. If it doesn't and DMEK does result in superior visual outcomes then we need to improve the complications of DMEK such as graft loss during preparation, rebubbling, and endothelial cell loss. Edward J. Holland, M.D., cornea editor W hen it comes to corneal endothelial disorders, endothelial keratoplasty has become popular with ophthalmologists worldwide, and many choose between Descemet's stripping endothelial keratoplasty (DSEK) and Descemet's membrane endothelial keratoplasty (DMEK). DSEK seems to be the current preferred method, with developments in DMEK causing the technique to gain ground. DSEK involves a transplant of the back layers of a donor cornea into a patient's eye. This technique offers a certain ease because it has been the procedure of choice for many years. DSAEK is the automated version of this procedure, which uses a machine to cut tissue. DMEK, on the other hand, uses extremely thin donor tissue, with a better chance of restoring good vision to the patient. However, surgeons using this technique often experience obstacles with handling the donor tissue because of how fragile the grafts can be. Recently, thin DSAEK has offered an alternative to the other two techniques, utilizing the ease of DSAEK with thinner grafts. Massimo Busin, M.D., Villa Igea Hospital, Forli, Italy, is one of the surgeons who has been seeing the benefits thin DSAEK can offer, and he compared the advantages and disadvantages doctors see using both DSAEK and DMEK. Similarly, Andrea Ang, M.D., Royal Perth Hospital, Perth, Western Australia, prefers using the thin DSAEK technique, but she also pointed out the advantages of both DSAEK and DMEK. Meanwhile, Francis Price, M.D., Price Vision Group, Indianapolis, favors DMEK and stressed some of its key advantages. The outcomes of each technique "Both techniques have developed because the results of the old conventional penetrating keratoplasty were not as satisfactory as one would like them to be," Dr. Busin said. Advancements were initially made by DSAEK, he said. However, he said that some physicians felt that there was only a limited number of eyes gaining 20/20 vision after surgery. This Preparation of DMEK tissue Source: David Vroman, M.D. prompted the development of DMEK, which was an attempt to increase the number of eyes that would be able to obtain 20/20 vision after surgery. Dr. Ang agreed with the advantages of DSAEK over penetrating keratoplasty and also with the argument that only a limited number of patients achieve 20/20 vision. "Recent DMEK studies have shown faster visual rehabilitation and better visual outcomes than the earlier DSAEK studies," Dr. Ang said. "However, recent studies have shown that the thickness of donor tissue used in DSAEK does influence visual outcome, with newer thin DSAEK techniques demonstrating improved visual outcomes approaching the visual outcomes seen with DMEK and with less complications." One of the reasons many surgeons tend to prefer DSAEK to DMEK is simply the ease with which the surgery can be performed. "It's much easier to perform a DSAEK, even with a thin graft, than it is to perform a DMEK," he said. To back up his point, Dr. Busin said that in the U.S. last year, there were over 21,000 DSAEK procedures, compared to around 343 DMEK procedures. Dr. Ang said new insertion devices like the EndoSerter (Ocular Systems, Winston-Salem, N.C.), the Busin Glide (Moria, Antony, France), and the Tan EndoGlide (Angiotech, Vancouver, B.C.) help to handle the tissue for insertion. "At the present, thin DSAEK appears an attractive alternative while DMEK techniques continue to improve," she said. Complications arising Despite DSAEK standing out as the easier technique, there are other factors to consider. DSAEK is often preferred to DMEK because primary failure is more common with DMEK, Dr. Busin said. He said DMEK poses the threat of a significant detachment rate. However, he also said DMEK typically has a lower rejection rate. Dr. Ang said "safety in donor preparation and easier manipulation of the tissue in the anterior chamber" is a factor that continues to make the DSAEK technique more popular. "The challenge for thin DSAEK is for the eye banks to come up with techniques to provide reproducible and accurate thin tissue," she said. Tissue loss and possibility of endothelial cell loss because of difficulties manipulating the delicate tissue were two possible risks with DMEK that Dr. Ang cited. "Solutions to these problems need to be found in order to make DMEK the procedure of choice for endothelial replacement," she said. continued on page 32

Articles in this issue

Archives of this issue

view archives of Eyeworld - JAN 2013