Eyeworld

SEP 2022

EyeWorld is the official news magazine of the American Society of Cataract & Refractive Surgery.

Issue link: https://digital.eyeworld.org/i/1475139

Contents of this Issue

Navigation

Page 72 of 90

70 | EYEWORLD | SEPTEMBER 2022 C ORNEA Relevant disclosures Koch: Alcon, Bausch + Lomb, Carl Zeiss Meditec, Johnson & Johnson Vision Miller: Alcon, Oculus Contact Koch: dkoch@bcm.edu Miller: kmiller@g.ucla.edu if you ask them if they've had prior eye surgery, many say no. Dr. Miller said they don't necessar- ily consider LASIK to be "eye surgery." Topog- raphy, tomography, or OCT "will save you from doing surgery on people you didn't know had refractive surgery," he said. "You think you should be able to see this prior surgery when you examine them, but you can't see PRK, and in some eyes it is difficult to see LASIK. The edge of the LASIK flap is just so well healed, it looks normal," he said. A biometry measurement is unlikely to reveal prior refractive surgery, Dr. Miller said, unless the cornea is significantly flatter than you think it should be, but even that is nuanced with lower treatments. 7. Onboarding new equipment. When you bring in a new imaging modality, Dr. Miller said to take time to evaluate it against the imaging you were using before. "I will continue doing the old thing, image them with the new thing, and retrospective- ly look at if I chose to go with the old thing, will the new thing give me a better outcome?" he said. "I think every time we bring in new equipment, you need to evaluate it in some way and … not just suddenly flip over to the new and abandon what you were doing before and maybe getting good results with." 'Garbage in, garbage out' Every instrument has its own quirks, and you've got to pay attention to various factors to get a quality image and measurement for IOL selec- tion, Dr. Miller said. "There is a famous computer saying: Gar- bage in, garbage out. If you have a person not looking in the right direction, their eyes are dry, their head is tilted 30 degrees, guess what? You're going to get terrible information by which to operate on," he said Lens power formulas are looking for inputs, values, Dr. Miller continued. There are many possible inputs, but the most important ones are corneal curvature and axial length. Of these, he said axial length is the most important to nail, with small errors in measurement resulting in large errors in lens power. Biometers do a good job of this, Dr. Miller said. For corneal power, Dr. Miller said most oph- thalmologists still use biometers, but he thinks Scheimpflug and OCT devices that look at the front and back surface of the cornea are best for calculating a toric lens. "I think measuring corneal power with these devices and planning out your astigma- tism management is better than using a simple biometer," he said. continued from page 69 The ablation in this tomography map is slightly decentered. Decentered ablations can almost never be seen on slit lamp biomicroscopy. Regular corneal astigmatism can be observed in the central portion of the map. Source (all): Kevin M. Miller, MD

Articles in this issue

Links on this page

Archives of this issue

view archives of Eyeworld - SEP 2022