Eyeworld

OCT 2018

EyeWorld is the official news magazine of the American Society of Cataract & Refractive Surgery.

Issue link: https://digital.eyeworld.org/i/1035656

Contents of this Issue

Navigation

Page 71 of 142

69 EW FEATURE October 2018 • Revisiting astigmatism While he said that the accuracy and repeatability of optical biome- try has dramatically improved their refractive outcomes, as have the latest generation of IOL formulas such as the Barrett and Hill-RBF, Dr. Raviv admitted that "[t]he variability in our K measurements and inability to accurately measure the posterior cornea still remain a challenge." "In fact, Graham Barrett's latest formula improves its refractive out- comes by allowing multiple device K readings instead of just one," he said. Dr. Raviv routinely uses three different devices—the LENSTAR, Cassini Total Corneal Astigmatism (Cassini Technologies, The Hague, the Netherlands), and a Topcon autorefractor/keratometer (Topcon Medical Systems, Oakland, New Jersey)—and more, if indicated. "For irregular eyes, we'll also utilize a Placido disc-based topographer." Each device has its strengths and weaknesses. "For IOL calcula- tions, LENSTAR or IOLMaster 700 Ks are the best, auto-Ks are pretty accurate," Dr. Raviv said. "Sim Ks from Placido-based devices are more approximate and shouldn't be plugged into formulas except in extreme cases such as keratoconus when other keratometers fail. I find that Ks from Scheimpflug topog- raphers are the least ideal for IOL calculations." "In an ideal situation, all of these measurements will be consis- tent," Dr. Donaldson said. "How- ever, in some cases … the measure- ments will differ. In those cases, we need to determine why there is a discrepancy and treat the underlying cause. The most common cause is ocular surface disease." Ocular surface matters "As part of our standard cataract evaluation, my technicians perform an Ocular Surface Disease Index questionnaire, tear osmolarity, and MMP-9 test," Dr. Donaldson said. "This allows us to assess both signs and symptoms of ocular surface disease in preparation for surgery. In addition, if measurements are inconsistent or if irregularities are detected during topography or tomography, the patient should be brought back for additional measurements to ensure reliability before surgery." In case of ocular surface disease, Dr. Donaldson initiates treatment and brings the patient back for fol- low-up evaluation a few weeks later. "I think it's important when you're assessing astigmatism to not forget the ocular surface," Dr. Gupta said. "At my clinic I routinely look at osmolarity and meibography, but a simple thing that you can also do is use a little fluorescein strip to highlight any corneal staining that might alter the pattern of the astigmatism." Dr. Thompson also cautioned against using measurements from untreated dry eye, but added that surgeons and their technicians should think about acquisition time; as noted earlier, the technique used to measure astigmatism using any device may introduce variables. "It's not only about the ocular surface but also about technician comfort and speed of acquiring information so the tear film doesn't break up and negatively affect our measure- ments," he said. Again, the use of multiple devices can highlight the presence of ocular surface problems. Dr. Raviv noted that variable measure- ments among different devices may indicate one of three possibilities: "poor wettability" of the cornea from ocular surface disease or dry eye; an irregular corneal surface that destabilizes the overlying tear film; or a subtle ptosis, enough to create variability between blinks. "I address variable Ks from oc- ular surface disease by priming the ocular surface (with preservative-free tears, steroid drops, LipiFlow [Johnson & Johnson Vision, Santa Ana, California], IPL [intense pulsed light], immunomodulator, as indi- cated) and repeating measurements a few weeks later," he said. "With epithelial basement membrane dys- trophy patients, there is the option to perform a superficial keratectomy, especially if an advanced technolo- gy IOL is requested." Adjustability and true measurements In the future, Dr. Donaldson looks hopefully toward IOLs that are adjustable postoperatively and that will be less dependent on preop- erative measurements. The Light Ad- justable Lens (RxSight, Aliso Viejo, California), for instance, already allows some surgeons to fine-tune their postoperative refractive results. Postop adjustability certainly makes preop astigmatism mea- surement "less impactful, but at the same time we want to go into surgery with the most accurate mea- surement so we either don't need to adjust IOL power postoperatively or it's a smaller adjustment," said Dr. Thompson, who has experience with the LAL as a principle investi- gator in the RxSight United States FDA monitored clinical trials. Dr. Gupta also thinks that preop astigmatism measurement will remain valuable despite the ability to adjust postop. Among other things, LALs are only current- ly available as a monofocal. Preop astigmatism management will thus remain critical for patients who need presbyopia-correcting IOLs. In addition, there may be patients who are unable to come back and forth for additional measurements and for the lock-in procedure after LAL implantation. More critical developments may come in terms of how physicians measure astigmatism through the entire cornea. "There's a key concept called total corneal astigmatism, which is a combination of the ante- rior and posterior corneal astigma- tism," Dr. Gupta said. "We are still looking for that device that gives us true total corneal astigmatism … potentially even have devices that measure the true value as opposed to an approximated value." At the moment, devices only provide posterior corneal astigma- tism measurements based on demo- graphic assumptions, Dr. Thomp- son said. Future technologies will hopefully give surgeons true, direct measurements of both the anterior and posterior corneal astigmatism. Dr. Raviv said that he sees work toward improving posterior ker- atometry and total corneal astigma- tism measurements being done via color LED and swept-source OCT. In addition, more topographers are beginning to noninvasively measure tear breakup time and other dynam- ic tear film-related variables, "which may help us know when to trust our Ks and when not to, as well as better monitor our dry eye treatments." In any case, Dr. Donaldson said, "in the shorter term, cataract surgery is becoming more custom- ized, requiring extensive attention to detail and high-level, time-con- suming preoperative evaluations to help meet the expectations of a population that thinks that cataract surgery will provide them vision that compares with LASIK and other corneal refractive procedures of the 21st century." EW Editors' note: Dr. Donaldson has finan- cial interests with Alcon (Fort Worth, Texas), Johnson & Johnson Vision, and Bausch + Lomb (Bridgewater, New Jersey). Dr. Raviv has financial interests with Cassini Technologies and Johnson & Johnson Vision. Dr. Thompson has financial interests with Johnson & Johnson Vision, Alcon, Avedro (Waltham, Massachusetts), Bausch + Lomb, RxSight, and Carl Zeiss Meditec. Dr. Gupta has no financial interests related to her comments. Contact information Donaldson: kdonaldson@med.miami.edu Gupta: preeya.gupta@duke.edu Raviv: TalRaviv@EyeCenterofNY.com Thompson: vance.thompson@vancethompsonvision.com

Articles in this issue

Links on this page

Archives of this issue

view archives of Eyeworld - OCT 2018